PYXIS SIGNAL AMPLIFIER
SIGNAL AMPLIFIER FOR PYXIS LOAD CELLS
PRODUCT INFORMATION
Pyxis is a microprocessor-controlled, compact and easy-to-use analog load cell amplifier.
It is installed in flexo, gravure, cutting, etc. machines to detect the tension of laminates. Its HW/SW configuration reduces signal processing times and allows up to four load cells to be connected.
Pyxis has only 3 calibration and programming buttons, and a 3-digit display that shows the selected function or tensioning value at all times.
Both load cell inputs and outputs for connection to your PLC or actuator system can be selected in voltage (mV) or current (mA).
TECHNICAL DATA
Power supply | 24 Vdc (18 ÷ 30 Vdc max.) |
Consumption | 250 mA max. |
Working temperature | 0 ÷ 50 ° C |
Tickets | 0 ÷ 60 mV / 4 ÷ 40 mA for load cells |
Analog output | 0 ÷ 10 V or 4 ÷ 20 mA selectable |
Analog outputs | 2 for 0 ÷ 10 V with adjustable digital filter for remote viewing or amplified input |
Digital relay outputs | 2 for 24 Vdc / Vac for alarms |
Outputs | 24 Vdc for remote display provisioning |